Warning
titleSuccessor available

This device is no longer available for sale and has been replaced by Wireless M-Bus Gateway V3 since 12/2021.

Overview

The Lobaro Wireless M-Bus Gateway V2 is a simple to use, cost and energy efficient device that receives, caches and forwards metering consumption data from up to 500 Wireless M-Bus enabled devices, like water meters, electricity meters, heat meters onto the Internet.

...

Note: The Lobaro IoT platform is fully optional! Image shows product with design cover accesssory.

Basic work cycle

Quick start guide

  • Make sure SIM card and battery are correctly connected.
  • Go to The Lobaro Platform and log into your account.
  • Go to "Devices" and select your "Lobaro NB-IoT wMBus Gateway".
  • If you have several Gateways: the "Address" is printed on the device's case.
  • You should see all wMBus Telegrams the Gateway collected so far.
  • If the data is encrypted (closed lock symbol 🔒), you can add keys for your devices under "Organisation → wMbus".
  • Push the reset button inside the device, if you want to trigger data collection (will take several minutes).

Compatible meters

The Lobaro wMBUS Gateways are working with every meter using standard 868 MHz wMbus:

...

Info

For more details please refer to our Wireless M-BUS article on doc.lobaro.com.


Setting up the device

  1. RESET Button
  2. SIM Card Holder (Nano SIM, 4FF)
  3. Connector for Lobaro USB-Config Adapter (Config, Logs, Firmware Updates)
  4. 2-Pin JST XH Stecker (3.3 - 5V, e.g. for 3.6V Battery)

SIM card

A SIM card is needed by the Gateway to connect to the mobile network. The drawing on the PCB displays the correct orientation of the SIM. The contacts must face down.

We can recommend 1nce.com for NB-IoT Connectivity. The device supports all Providers on Band 8 and Band 20. 

Power supply

The Gateway is powered by a 3.6V D-Cell battery, that is connected via a XH connector (a white 2 pin socket on the board, labeled "VBat 3V6"). If the battery is initially not connected to the board, you will need to plug in the XH connector. When the device powers up, the on-board LED will blink green once.

Resetting the device

Inside the device on the board is a button labeled "RESET". If you push this button while the device is running, it will stop and reboot. You should see a green flash of the LED when the device starts again. Disconnecting the battery from the device will not be enough to reboot the device! The Gateway buffers enough energy to run for several minutes without a power supply connected (the actutal time is depending on what the Gateway does during that time).

Configuring the device

If you purchased your Lobaro wMBus Gateway with a SIM card included and you are using the Lobaro Platform, you will not need to change any configuration for the device to work. Instructions on how to change the device's configuration using the Lobaro Config Adapter can be found on the Device Configuration on the manual page for our Configuration Tool.

Mobile operator and LTE band configuration

If you are using a different mobile operator than pre-configured, you should change the mobile operator code set in the Config Parameters Operator and (LTE) Band Operator codes are 5 digit codes that indicate country and operator.

...

Info

For details about configuration for mobile network operation please refer to our article about LTE / NB-IoT Networks


Configuration

The configuration can be read or changed locally via USB and the Lobaro Maintenance Tool or remotely using the Lobaro IoT Platform (NB-IoT only).

Configurations of up to 5000 bytes are supported, which enables a Device-Whitelist of up to 500 Meter-IDs.

General Parameters

NameDescriptionDefault ValueValue Description & Examples
WANRadio technology used for data uploadslte"lte": use cellular NB-IoT for uplinks
"lorawan": use LoRaWAN for uplinks
 (working like Wireless M-Bus Bridge V2)

NB-IoT Parameters (WAN = "lte")

The NB-IoT functionality is enabled if the WAN parameter is set to "lte". A SIM-Card has to inserted.

NameDescriptionDefault ValueValue Description & Examples
HostHostname / IP of the Lobaro Platform API94.130.20.3794.130.20.37 = backend.lobaro.com (warning) DNS is not supported yet
PortPort number of the Lobaro Platform API5683

UdpHostSeparate IP to upload plain telegrams via UDP
optional, empty = upload to Lobaro IoT Platform
UdpPortSeparate Port to upload plain telegrams via UDP0only used when UdpHost is set
OperatorMobile Operator Code2620126201 (=Deutsche Telekom), for other operators, see above.
BandNB-IoT Band8"8", "20", "8,20", Empty = Auto detect (longer connecting time)
APNMobile operator APNiot.1nce.net

1nce: iot.1nce.net

Vodafone Easy Connect: lpwa.vodafone.com (l = littel L)


PINSIM PIN (since v0.7.0)
Empty or 4 digits (e.g. 1234)
UseNbiotTry to connect with NB-IoTtrue

UseLtemTry to fallback to LTE-M when supported by the Modemfalse(warning) not supported with all Hardware revisions

LoRaWAN (WAN = "lorawan")

(warning) The LoRaWAN functionality is enabled if the WAN parameter is set to "lorawan". In this mode the device behaves like the LoRaWAN only "Wireless M-Bus Bridge V2", consider also reading its manual when using the LoRaWAN functionality of the Wireless M-Bus Gateway V2 (NB-IoT). No SIM-Card is needed.

...

NameDescriptionDefault ValueValues
OTAAActivation: OTAA or ABPtruetrue= use OTAA, false= use ABP
DevEUIDevEUI used to identify the Device
e.g. 0123456789abcdef
JoinEUIUsed for OTAA (called AppEUI in v1.0)
e.g. 0123456789abcdef
AppKeyKey used for OTAA (LoRaWAN v1.0.x and v1.1)

NwkKeyKey used for OTAA (LoRaWAN v1.1 only)

TimeSyncDays after which to sync time over LoRaWAN 3

days, 0=don't sync time
(does not effect LTE, which always executes daily time syncs)

RndDelayRandom delay before sending (avoids collisions)10max seconds
PayloadFormat
  • 0 = Encoding in ports
  • 1 = prefix bytes and time
  • 2 = prefix bytes, time, and rssi
0For details see manual of wMBUS LoRaWAN bridge
LostRebootDays without downlink before reboot5days, 0=never reboot

Metering reception Parameters

NameDescriptionDefault ValueDefault Values & Examples
listenCron

Cron expression defining when to receive wMBUS

Introduction to Cron expressions.

0 0 12 * * *

0 0 12 * * * = (once per day)

cmodeDurSecDuration (Seconds) of wireless M-Bus C1/T1-mode receive3000= Do not collect C1/T1 mode
smodeDurSecDuration (Seconds) of wireless M-Bus S1-mode receive00= Do not collect S1 mode
xmodeDurSec Duration (Seconds) of Sensus RF receive0 0= Do not collect Sensus RF telegrams
mFilterwMBus manufacturer filter sep. by , e.g. dme,itw (Comma separated list WITHOUT spaces)

blank=no filter,  (warning) not used for xmode (Sensus RF)
typFiltermeter device type filter e.g. 08,07 for Heat Cost and Water (Comma separated list WITHOUT spaces)

blank=no filter, (warning) not used for xmode (Sensus RF)

Expand
titleType Codes
00: "Other",
01: "Oil",
02: "Electricity",
03: "Gas",
04: "Heat",
05: "Steam",
06: "Warm Water", // 30 - 90°C
07: "Water",
08: "Heat Cost",
09: "Compressed Air",
0A: "Cooling load meter (outlet)",
0B: "Cooling load meter (inlet)",
0C: "Heat (inlet)",
0D: "Heat / Cooling load meter",
0E: "Bus / System component",
0F: "Unknown",
10: "consumption meter",
11: "consumption meter",
12: "consumption meter",
13: "consumption meter",
14: "Calorific value",
15: "Hot Water", // >= 90°C
16: "Cold Water",
17: "Dual Water meter", // Hot and Cold
18: "Pressure",
19: "A/D Converter",
1A: "Smoke detector",
// 1B - DD: "Reserved"
1B: "Room", // e.g. temp, humidity
1C: "Gas detector",
1D: "Sensor",
1E: "Sensor",
1F: "Sensor",
20: "Breaker (electricity)",
21: "Valve (gas or water)",
22: "Switching device",
23: "Switching device",
24: "Switching device",
25: "Customer unit (display device)",
26: "Customer units",
27: "Customer units",
29: "Garbage",
2A: "Carbon dioxide",
30: "system device",
31: "Communication controller",
32: "Unidirectional repeater",
33: "Bidirectional repeater",
34: "system device",
35: "system device",
36: "Radio converter (system side)",
37: "Radio converter (meter side)",
38 - 0x3F // Reserved for system devices
40 - 0xFE: Reserved
FF: "Invalid", // Wild card searching [EN 13757-3:2013], 11.3 and 11.5.3


devFilter

meter id filter e.g. 

  • cmode, smode (wmbus): 06198833 (exactly 8 digits with leading 0)
  • xmode (Sensus RF): 10121335300 (11 digits, no "-"!)

(Comma separated list WITHOUT spaces: 88009035,13456035,56268931)

Up to 500 wMBus-IDs or 400 Sensus-RF-IDs are supported.


blank=no filter
ciFilter

Collect only telegrams with specific values in the ci-Field, must we written as 2 hex digits (with leading zeros).

(Comma separated list WITHOUT spaces, e.g.: "8a,07,71")


blank=no filter, (warning) not used for xmode (Sensus RF). Since v0.9.0
maxTelegrams

Set hard limit on how many telegrams will be collected and uploaded. The bridge will stop collection, once this number has been collected, regardless of the passed time. Can be used save battery / data volume, should the device be in an area with a large number of meters.

Set to 0 for no limit.


Since v0.8.5

 See also our Introduction to Cron expressions.

Modes of operation (work cycle)

This chapter explains how the device works to collect and upload wireless Mbus data.

  1. Wakup at listenCron / On start up of device ignore listenCron always run following steps.
  2. Collect C-Mode and T-Mode telegrams for cmodeDurSec (if not 0)
  3. Collect S-Mode telegrams for smodeDurSec (if not 0)

  4. Collect X-Mode telegrams (Sensus RF) for xmodeDurSec (if not 0)
  5. Upload all stored data via NB-IoT / LTE-CatM1 or LoraWAN (see "WAN" configuration)
    1. When the upload fails the upload is retried every 24h or until the next listenCron trigger.
  6. Sleep till next listenCron or status telegram upload.

Deduplication

When collecting wMbus telegrams, duplicates are always replaced by the latest telegram in memory. This leads to only 1 Telegram per Type and Meter per upload phase.

...

  • The actual length of the telegram is the same
  • The ID is the same
  • The CI-Field is the same


Mobile data consumption

Uploading one wMbus telegram consumes approximately 400 bytes data including all metadata.

...

All calculations are estimations and might varry depending on the configuration

The Lobaro Platform

The easiest way to work with the Lobaro wMBus NB-IoT Gateway is the Lobaro Platform. You can find it under https://platform.lobaro.com – Log in with the credentials provided by Lobaro.

Your Gateways should be listed under "Devices". If you have multiple devices in your account, you can distinguish them by the field "Address". The Address is printed on the box of the Gateway (the Address is the IMEI of the modem used by the device; that is the unique hardware address used for mobile communication).

Displaying wMBus data

Open the tab "Device Data" to see a list of all Wireless M-Bus telegrams that your Gateway uploaded.


Changing configuration

You can see and edit the configuration of the Gateway without physical access to the device from the Lobaro Platform. Open the tab "Config" for your device. The current configuration will be shown. You can edit individual config entries by clicking on the pencil. After you entered all the values you want to change, click the "Update config" button. The new configuration will be sent to the device the next time it uploads data to the platform. After changing the configuration, it will reboot and start working with the new config.

...

The remaining configuration parameters (Host, Port, APN, Band, ...) are used to configure the way the device connects to the mobile provider and to the Lobaro Platform. There is no need to change these values when using the Gateway with the Lobaro Platform.

wMBus encryption Keys

Many meters are sending encrypted data. In order to get the values out of that encrypted telegrams, you will need to provide the decryption key to the Platform. Go to "Organisation" / "wMBus" to add encryption keys. You will need to set a key for a specific meter (identified by its ID).

Once a key is entered for a device, any telegram received after that will be decrypted and listed in clear text under "Device Data".

Forwarding data to your own system

If you want the received data inside your own system, you can add an Integration inside the Lobaro Platform that forwards all data to your system. We currently supply a REST API that allows you to query data from our platform actively, as well as a HTTP(S) integration, that pushes incoming data to your system when it is received.

Configuration with the Config Adapter

Instead of using the Lobaro Platform, you can use the Lobaro Config Adapter and the Config Tool to change the Configuration directly in your hardware. This can be useful when you want to change configuration while the mobile connection does not work (or if you do not want to use the Lobaro Platform). See Lobaro USB configuration adapter for more information.

Using Raw UDP

In default configuration, the Gateway communicates using CoAP with messages that are designed to work with our Lobaro Platform as a backend. If you want to connect the Gateway directly to your own backend, it can be hard to implement an endpoint.

CBOR messages over UDP

Starting with Firmware version 0.5.0, the Gateway supports a second format, where wMBus telegrams are uploaded without CoAP over UDP. When the configuration Parameters UdpHost and UdpPort are set to a destination (IP address and port number), wMBus telegrams will be sent to that destination instead of the Lobaro Platform. It will be sent as a CBOR object using raw UDP packets without CoAP. CBOR can easily be parsed in most programming languages using existing libraries. It is similar to JSON but uses a binary representation.

...

The "telegram" part can be decoded using our wMbus Parser API at https://platform.lobaro.com/#/wmbus/parser

Controlling the device

When UdpHost and UdpPort are set while Host and Port are referring to the Lobaro Platform, the Gateway will upload the wMBus telegrams to the UDP destination but will also sent diagnostic messages to the Platform. In this configuration you can still use the features of the Lobaro Platform to control the device for configuration changes or firmware updates, while receiving your wMBus data directly to your own backend.

Format

Schema

The CBOR object contains the following information

...

NameExplanation
rssiReceived signal strength indication indicating the quality of the received signal.
vbatSupply voltage to the Gateway, measured in millivolts (mV).
monitorHuman readable diagnostic string. The format of this information subject to change and should not be relied on.
telegramBytes of the received wMBus telegram as a byte string.
timestampTime of reception of the telegram in the gateway, given as a Unix Timestamp.
temperatureTemperature inside the Gateway, measured in tenth of Degree Centigrade (d°C).
iIMEI of the Gateway's Modem, uniquely identifying the Device.
nFrame number. Starts at 1 for the first UDP-upload after boot and is increased for every upload.


Example

The following shows an example message if you display it as JSON. In the CBOR object, the telegram is stored as a byte string. Because JSON does not support binary data, in this example it is encoded using base64.

...

UDP-Uplink #7 from Gateway with IMEI 123456101550542
Status of Gateway during upload:
  internal Temperature: 24.0°C
  supply Voltage: 3.688V
  Mobile provider, Cell-ID: 019C1307
Received wMBus Telegram:
  time of recept: 2020-07-08T09:45:36 (UTC)
  telegram (as hex): 49449344790501883408780dff5f350082670035c8bf55ad3c5b1ed6661c65940b88f47f6ae8c5f5ee3a99e101e82224c4998750477ac4f7409a8a77baa22de3258c81bc046d3a0a8827
  rssi: -99

LED blinking patterns

The device has an RGB-LED to give visual feedback.

...

WhenPatternExplanation
on resetshort green flash every ~15s

Configuration is invalid

on resetshort green flash every ~25sSIM-Card cannot be read
during operationsblue on/off once per secondTrying to connect to mobile provider
during operationsblue on/off once per second, then greenTrying to connect to mobile provider, success
during operationsblue on/off once per second, then redTrying to connect to mobile provider, failing

Housing Specification & Accessories

The Lobaro wireless Mbus bridge uses the TG PC 1208-6-o feature rich IP67 housing from Spelsberg.

For the housing the following accessories are available on request:

Housing Design Cover

For a cleaner look of the device a addon design cover is available. Order number: 8000140

External fixing lugs (TG ABL):

Allow the mounting without opening the (sealed) cover. Order number: 3000104

Sealing kit (TG PST1):

May be used to seal the box to complicate unauthorized access to the device.

Troubleshooting

I did not get a username/password for the Lobaro Platform.

Please contact contact Lobaro to get your account information.

I do not see my Gateway listed unter "Devices".

It is possible that the purchased device has not been added to your account. Please check if you got an Activation Code with your hardware. If so, you can enter it under "Tools" / "Hardware Activation" in order to claim the device for your account.

I cannot find data for my specific meter.

Make sure your Gateway collected data since you brought it close to the meter (check timestamps on data). With standard configuration, it only collects data every 8 hours. You can press the "RESET" Button inside the device to make it reboot and start collecting data.

Also check the specifications of your wMBus meter. How often does it send data? What mode does it use? Using standard configuration, the wMBus Gateway only collects C-Mode and T-Mode telegrams. If your meter is sending S-Mode, you will need to change the Gateway's configuration.

Data for my meter only shows "Payload encrypted".

Most meters encrypt the data they are sending out (information about water/energy usage is personal data). In order to see values from encrypted wMBus telegrams, your will need to supply the decryption key for your meter (you should be able to get the key where you got the meter). You can add the key in the Lobaro Platform under "Organisation" / "wMBus". You will have to add a key for a specific meter (identified by the meter's ID).

After you supplied the key, new telegrams that are received should be decrypted so that you can see the values inside the telegram.

How can I check the NB-IoT Signal quality?

Signal quality comes from the Modem Monitor string: "RSRP:13(0/4), RSRQ:5(0/4), SNR:19(1/4)"

...

  • 0 rsrq < −19.5 dB
  • 1 – When −19.5 dB ≤ RSRQ < −19 dB
  • 2 – When −19 dB ≤ RSRQ < −18.5 dB
  • ...
  • 32 – When −4 dB ≤ RSRQ < −3.5 dB
  • 33 – When −3.5 dB ≤ RSRQ < −3 dB
  • 34 – When −3 dB ≤ RSRQ
  • 255 – Not known or not detectable


Safety Instructions