The EDL21 over LoRaWAN bridge is a device that can be used to readout modern utility meters with standardized infrared "INFO" interface.
These type of meters are called in Germany to be "EDL21"-compatible - hence the name. The meter outputs over its infrared "INFO" interface a serial protocol conforming to the Smart Meter Language Protocol 1.04 (SML). This interface is intended to be used by end-users and not for billing purposes of the electricity supplier. The read information normally contains the current consumption values of the meter and gets interpreted and forwarded by the EDL21 bridge via a LoRaWAN network to web based applications interested in further processing this data.
Older meters with "infrared pulse" output are not compatible to the Lobaro EDL21 bridge. Please check our list of compatible meters to make sure it is equipped with the correct interface. |
LoRaWAN 1.0.x and 1.1 network servers supported
LoRaWAN time synchronisation
Configuration via USB or remotely via LoRaWAN downlink
Compatible with many electrical utility meters
Configure up to 25 Obis Codes to be read
RGB Status LED
Separation of infrared readout head possible
Testmode for protocol and supported obis code identification
Any meter that adheres to the standard can be read. The following list contains meters that we successfully tested.
Electricity meter | Manufacturer |
---|---|
DTZ541-ZEBA | Holley |
LK13 series | Logarex |
OpenWay® 3.HZ | iTron |
SGM-C4 series | efr |
SGM-D series | efr |
eHZ-K series | EMH |
mMe4.0 series | EMH |
ED300 series | EMH |
eBZD series | EMH |
E320 | Landis+Gyr |
MT681 | ISKRA |
Alternative IEC 62056-21 protocol On request we offer also the integration of electricity meters using the D0 interface conforming to IEC 62056-21. This interface is not compatible to the SML protocol. Please contact us if you need an offer for a custom firmware supporting your meter of interest. |
EDL21-LoRaWAN Bridge (universal head, current transformer, int. Ant.), Order number: 8000160
The product variant shown above is the standard variant. Other power supply options & housing are available on request
Contact us via support@lobaro.de if you need our offer for a special variant. |
Battery Pack, Order Number: 8000164
The optional Battery Pack has 2 functions. The main function is to supply the device with energy for initial testing without having to wait for the current transformer. After connecting the battery pack for the first time it will take about 30 seconds to load the bridges supercapacitor. The secondary function is to provide a simple way to reset the device with an inbuilt magnet. If the red dot on the battery pack is brought near the bridge the bridge will signal its presence by activating its LED. After 1 second it will blink rapidly and reset.
The configuration is done using Lobaro Maintenance Tool and the Lobaro USB PC adapter.
The connection to the LoRaWAN network is defined by multiple configuration parameters. This need to be set according to your LoRaWAN network and the way your device is supposed to be attached to it, or the device will not be able to send any data.
For a detailed introduction into how this values need to be configured, please refer to the chapter LoRaWAN configuration in our LoRaWAN background article.
Name | Description | Type | Values |
---|---|---|---|
OTAA | Activation: OTAA or ABP | bool | true = use OTAA, false = use ABP |
DevEUI | DevEUI used to identify the Device | byte[8] | e.g. 0123456789abcdef |
JoinEUI | Used for OTAA (called AppEUI in v1.0) | byte[8] | e.g. 0123456789abcdef |
AppKey | Key used for OTAA (v1.0 and v1.1) | byte[16] | |
NwkKey | Key used for OTAA (v1.1 only) | byte[16] | |
RndDelay | Random delay before sending | int | max seconds |
RemoteConf | Enable Remote Configuration | bool | true =activate, false=deactivate |
LostReboot | Days without downlink before reboot (triggers downlinks) | int | days, 0 =don't reboot |
Configuration values defining the behaviour of the device.
name | description | Type | Values |
---|---|---|---|
LoRaLevel | Minimum Voltage for packet transmission in mV | int | e.g. 3200 |
LowVoltageWarning | Voltagelevel that will trigger a Status Message with enabled Warning Flag | int | e.g. 2700 |
LogUart | Enables or Disables parts of the logging to save energy | bool | true = enabled, false = disabled |
ObisCode | Comma separated list of ObisCodes to select a subset of the available information | string | e.g. 1-0:1.7.255*255 = Leistung (Momentan) |
PayloadFormat | Format used for data upload (include timestamps or not) | int | 1 =no timestamp, 2 =include timestamp |
uploadCron | Cron expression defining when to read and upload | string | 0 0/15 * * * * for every 15 minutes |
TestMode | Enables Testmode to check compatibility | bool | true = enabled, false = disabled |
See also our Introduction to Cron expressions and our Introduction to Obis Codes.
The following pattery are explained in the order in which they appear after initial power on / reset of the device.
color | duration/repetitions | description |
---|---|---|
red/green/blue | 500 ms each | initial pattern after reset |
green | 300 ms | data message received |
red | 300 ms | no incoming data |
green | 300 ms | sml parser successful |
red | 300 ms | sml parser failed |
blue | 2 x 300 ms | LoRaWAN network join successful |
blue | 300 ms | sent LoRaWAN data uplink |
off | - | low-power mode until next sendout cycle |
Once per day a status packet will be sent. It contains basic information about the device. The Battery Voltage is transmitted in 1/1000 V and the temperature in 1/10 °C. Both are in Big Endian byte order.
Version Major | Version Minor | Version Patch | Flags | Battery Voltage | Temperature |
---|---|---|---|---|---|
1 byte | 1 byte | 1 byte | 1 byte | 2 byte | 2byte |
unsigned | unsigned | unsigned | unsigned | unsigned | signed |
The "Flags" field represents different error conditions by setting the individual bits:
Bit | Error Condition |
---|---|
0 (LSB) | Parsing the obis code failed |
1 | No incoming data from the opto head |
2 | Brown Out |
3 | None of the defined Obis Codes could be found in the incoming data |
4-7 | Unused |
This Format is used, when the configuration parameter PayloadFormat
is set to 1
(which is the default value).
The payload consists of multiple entries, one entry per OBIS code given in the configuration. Each entry follows the following structure:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
6 bytes | 1 byte | n bytes, LSB first | 1 byte (signed) |
Example packet: 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 ff 01 00 01 08 00 FE 08 FF 02 00 00 00 00 00 00 02
Entry 1:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
01 00 01 08 00 FE | 08 | FF 01 00 00 00 00 00 00 | ff |
1-0:1.8.0*254 | 8 | 511 | -1 |
Value = 511 * 10^-1 = 51.1 |
Entry 2:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
01 00 01 08 00 FE | 08 | FF 02 00 00 00 00 00 00 | 02 |
1-0:1.8.0*254 | 8 | 767 | 2 |
Value = 767 * 10^2 = 76700 |
The Bridge puts as many values in a single data message as possible (respecting the current Spreading Factor). When it cannot fit all values in a single message, it will send multiple data messages until all values are uploaded. It will never split a single value. Since every value is prefixed with the Obis code, the parser can easily assign values to Obis codes.
This Format is used, when the configuration parameter PayloadFormat
is set to 2
.
The Obis Codes and Data Values are transmitted as in Payload Format 1, but each uploaded LoRaWAN-Message with data is prefixed with a 5 byte Timestamp, indicating when the values where requested from the attached meter. This allows for a more precise timing information then using the time of reception, as the upload can be delayed quite heavily due to our random delay feature and potentially due to duty cycle restrictions. The timestamp also makes it easy to reassociate values from multiple uplinks to a single reading, when multiple uplinks must be used to upload all values. If a readout is spilt over multiple uplinks (because of LoRaWAN's length restrictions), every uplink from that reading will have the same timestamp (which is the time of requesting the values from the meter).
The Timestamp is sent as a UNIX-Timestamp encoded as a bigendian signed 40-bit number.
Be aware that the timestamps are generated using the device's internal clock, which does not necessarily represent real time! If you want exact timestamps, you should use the TimeSync feature that synchronises the device's clock over LoRaWAN. Be sure that your network server supports it. Even with incorrect clock, the timestamps can still be used to reassociate split uploads. For more information, please refer to the section on Timestamps in LoRaWAN of our LoraWAN background article. |
If TestMode is enabled in the configuration the device will not enter normal operation but check for different possible meter output protocols. Received data will be shown in the Log and parsed if possible. After completing the detection the result will be presented 10 times as blinking pattern via LED. After that the testing cycle will start again. The Log-Output can also be used to identify available OBIS Codes.
blinking pattern | description |
---|---|
1 x green | Ascii output without activation |
2 x green | SML |
3 x green | IEC 62056-21 |
1x red | no data received / data could not be parsed |
IEC 62056-21 protocol can be detected in testmode but is not yet supported in normal mode. |
This is a decoder written in JavaScript that can be used to parse the device's LoRaWAN messages. It can be used as is in The Things Network.
function readName(bytes, i) { return bytes.slice(i, i + 6); } function readValue(len, bytes, i) { if (len <= 0) { return []; } return bytes.slice(i, i + len); } function toHexString(byteArray) { var s = ''; byteArray.forEach(function (byte) { s += ('0' + (byte & 0xFF).toString(16)).slice(-2); }); return s; } function signed(val, bits) { if ((val & 1 << (bits - 1)) > 0) { // value is negative (16bit 2's complement) var mask = Math.pow(2, bits) - 1; val = (~val & mask) + 1; // invert all bits & add 1 => now positive value val = val * -1; } return val; } function uint40_BE(bytes, idx) { bytes = bytes.slice(idx || 0); return bytes[0] << 32 | bytes[1] << 24 | bytes[2] << 16 | bytes[3] << 8 | bytes[4] << 0; } function uint16_BE(bytes, idx) { bytes = bytes.slice(idx || 0); return bytes[0] << 8 | bytes[1] << 0; } function int40_BE(bytes, idx) {return signed(uint40_BE(bytes, idx), 40);} function int16_BE(bytes, idx) {return signed(uint16_BE(bytes, idx), 16);} function int8(bytes, idx) {return signed(bytes[idx || 0], 8);} function toNumber(bytes) { var res = 0; for (var i = bytes.length-1; i >= 0 ; i--) { res *= 256; res += bytes[i]; } return res; } function readVersion(bytes) { if (bytes.length<3) { return null; } return "v" + bytes[0] + "." + bytes[1] + "." + bytes[2]; } function decodeStatus(bytes) { var decoded = { "version":readVersion(bytes), "flags": bytes[3], "vBat": uint16_BE(bytes, 4) / 1000, "temp": int16_BE(bytes, 6) / 10, }; return decoded; } function decodeSmlValuesV1(bytes) { var decoded = { values: [], }; if (bytes.length === 1) { // No Data! Read error? return decoded; } var pos = 0; while (pos < bytes.length) { var name = readName(bytes, pos); pos += 6; var len = bytes[pos]; pos += 1; var value = readValue(len, bytes, pos); pos += len; var val = { nameHex: toHexString(name), len: len, value: toNumber(value), valueHex: toHexString(value) }; decoded.values.push(val); } return decoded; } function decodeSmlValuesV2(bytes) { var decoded = { values: [], }; if (bytes.length === 1) { // No Data! Read error? return decoded; } var pos = 0; while (pos < bytes.length) { var name = readName(bytes, pos); pos += 6; var len = bytes[pos]; pos += 1; var value = readValue(len, bytes, pos); pos += len; if (len > 0) { var exponent = int8(bytes, pos); pos += 1; } var val; if (len > 0) { val = { nameHex: toHexString(name), len: len, value: toNumber(value) * Math.pow(10, exponent), valueHex: toHexString(value), } } else { val = { nameHex: toHexString(name), len: len, value: toNumber(value), valueHex: toHexString(value), } } decoded.values.push(val); } return decoded; } function decodeSmlValuesV3(bytes) { // Like V2, but with 5B timestamp as prefix: var decoded = decodeSmlValuesV2(bytes.slice(5)); decoded.time = int40_BE(bytes, 0) * 1000; return decoded; } function Decoder(bytes, port) { // Decode an uplink message from a buffer // (array) of bytes to an object of fields. switch (port) { case 1: return decodeStatus(bytes); case 2: return decodeSmlValuesV1(bytes); case 3: return decodeSmlValuesV2(bytes); case 4: return decodeSmlValuesV3(bytes); } } |
Test input (Port 3): 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 FF { "values": [ { "len": 8, "nameHex": "0100010800fe", "value": 51.1, "valueHex": "ff01000000000000" } ] } |
Product | |
Type name | LOB-S-CUR-LW-EDL21 |
Description | Electricity meter over LoRaWAN Bridge |
RF transceiver | |
Type | Semtech SX1261 |
Frequency | 863 MHz to 870 MHz |
Max. TX Power | max. +14 dBm |
Typical RF Range | ≤2km |
Ideal RF Range | ≤10km (free line of sight) |
LoRa communication | |
Protocol | Class A LoRaWAN 1.0.1 EU868 |
Activation method | Over-the-air-activation (OTAA) Activation by personalization (ABP) |
Encryption | AES128 |
Environmental Requirements | |
Operating temperature | -20°C – 55°C |
Max installation height | 2m |
Standards |