Firmware

Downloads:

Firmware Release Notifications

We normally send e-mail notifications upon release of new firmware versions. To receive this mails you can sign up to the Lobaro newsletter here.

Subscribe to our email newsletter here

Make sure to select the "Firmware Updates" checkbox!

Starting with Firmware 0.5.0, the default values for JoinEUI (aka AppEUI), AppKey, and NwkKey in the configuration have changed. Be sure to check your LoRaWAN-Configuration between device and Network Server, after you update to this version.

You can adjust those values to your need with our config adapter.

Changelog

app-lorawan-onewire-bridge

This changelog's format is based on Keep a Changelog, and this project adheres to Semantic Versioning.

0.5.1 - 2020-10-15

Changed

  • Set standard value for config parameter LostReboot to 1 (from 0).

0.5.0 - 2020-08-12

Added

  • Power-On Selftest

Changed

  • BREAKING CHANGE: Default values for JoinEUI, AppKey, NwkKey changed!
  • Uses LoRaWAN-Stack that was certified for wMBus-Bridge
  • Implement changes in LoRaWAN-Stack that happend during certification. Implements some edge-case.
  • Make remote config feature robuster, e.g. when sending downlinks with ACK request.

Fixed

  • Fixed Mixup of Sensors that could trigger endless loop

0.4.1 - 2020-07-21

Fixed

  • Fix payload of sensor data

0.4.0 - 2020-06-30

Added

  • Start changelog.

Changed

  • Use lobawan stack v1.2.2
  • Sensors from SensorIdOrder that are missing will still be uploaded (with -0x8000 value)
  • When SendSensorId==false uploads are done on port 3 (was port 2),
  • Enable 3.3V step-up only if voltage is below 3.1V (was: if below 3.3V).
  • Support up to 32 sensors (only 25 supported in SensorIdOrder).

0.3.3 - 2019-08-01

  • Added ADR config parameter

0.3.2 - 2019-08-01

  • Fixed Onewire init after DeepSleep

0.3.1 - 2019-07-29

  • Temp sensors will be printed and sent sorted by parameter "SensorIdOrder" and by ID or just by ID if parameter "SensorIdOrder" is empty

0.2.0 - 2019-02-15

  • Add parameter "SendSensorId" to allow skipping sensor IDs in payload

0.0.3

  • Bugfixes in LoraWAN stack
  • LoRaWAN Support for RX1 DataRate Offset

0.0.2

  • Don't send sensor type with ID (support 6 sensors in 50 bytes)
  • Add TestMode config value
  • Add SendInternalTemp config value
  • Internal sensor is send first if SendInternalTemp = true