Address | Function | Bytes | Data Scope | Description |
---|---|---|---|---|
0x0000 | 0x03, 0x06 | 2 | 1-255 | Slave Address |
0x0001 | 0x03, 0x06 | 2 |
| Baud rate |
0x0002 | 0x03, 0x06 | 2 |
|
|
0x0003 | 0x03, 0x06 | 2 |
| Pressure unit |
0x0004 | 0x03, 0x06 | 2 |
| Decimal point stands for 0-4 digits |
0x0005 | 0x03, 0x06 | 2 | 0-30 | Filtering Coefficient |
0x0016 | 0x03 | 2 | -32768-32767 | Measurement Pressure output value |
0x0018 | 0x03, 0x06 | 2 | -32768-32767 | Master variable of Pressure offset |
0x001A | 0x03, 0x06 | 2 | -32768-32767 | Range minimum of Pressure Transmitter |
0x001C | 0x03, 0x06 | 2 | -32768-32767 | Range maximum of Pressure Transmitter |
0x001E | 0x03, 06 | 2 | -32768-32767 | Range minimum of Pressure Sensor |
0x0020 | 0x03, 06 | 2 | -32768-32767 | Range maximum of Pressure Sensor |
0x0026 | 0x03 | 2 | -32768-32767 | Measurement Temperature output value |
0xFFFF | 0x06 | 2 |
| Save data to user area |
0xFFFC | 0x06 | 2 |
| Restore to factory status (user settings and calibration data) |
...