Downloads:
current release | |
previous release | |
app-modbus-lora-bridge-0.3.1.hex | latest release with old stack version |
## Changelog `app-modbus-lora-bridge` – Reading modbus devices remotely over LoRaWAN. This changelog's format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/), and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html). ### 1.3.0 - 2020-12-16 WARNING: this version has some changes that could break your integration if you have a very specific parser! An undocumented Payload Format has been removed and the Status Message (Port 1) is 2 bytes longer. #### Changed - Replace broken compact payload formats (2 and 3) with new version (4 and 5). #### Added - Feedback by LED blinking patterns for success/failure reading data and otaa join. - Add Reboot Reason and Final Words to status message. - Add Config Parameter `PowerDelay` to control warm up time of sensors that are powered by the bridge. #### Fixed - Increase stack size for dialog mode. ### 1.2.2 - 2020-06-18 #### Changed - Using Lobawan 1.2.2 (fixes some issues with OTAA Joins). ### 1.2.1 - 2020-02-17 #### Added - Display Version of Lobaro LoRaWAN Stack on boot. #### Fixed - Fix a crash when using remote command `append`. ### 1.2.0 #### Added - New config parameter `MbAttempts` to control how often Modbus Commands will be repeated in case of timeouts. ### 1.1.1 #### Changed - Increased size available for config. ### 1.1.0 #### Added - New optional Listen-Before-Talk Modbus communication, so device can coordinate with another master on bus. #### Fixed - Fix issue that could cut of long Modbus responses. ### 1.0.3 #### Changed - Dialog Mode now logs activity on RS485 Bus while not communicating (to detect other Modbus Masters). - Log Frequencies for LoRaWAN. ### 1.0.2 #### Added - Wait cycles for optional capacitors to load and stabilize on startup ### 1.0.1 #### Changed - Using FRAM for storing results before uploading, allowing for multiple kB of data to be sent (size depending on hardware). #### Fixed - Removed memory corruption error that could be triggered by configurations with lots of Modbus commands. ### 1.0.0 #### Added - LoRaWAN 1.1 support - Remote configuration via LoRaWAN on port 128. - Clock synchronisation via LoRaWAN. #### Changed - Random delay before Uplink (to prevent persistent collisions when using multiple devices). - Modbus responses longer than payload now get split up (additional parts on port 5). ### 0.4.1 #### Fixed - Changed error indication bit on error 11 from `0xf0` to `0x80`. - Fixed issue when parsing multiple Modbus commands from config. ### 0.4.0 #### Added - Writing values to holding registers and coils. - Execution of arbitrary Modbus commands triggered by LoRaWAN Downlink messages. - Support for LoRaWAN Operation Mode Class C (for short reaction time to Downlinks). - Automated register writing and broadcasts possible through new configuration. #### Changed - Automated reading (triggered by cron) is now configured by entering actual Modbus commands (more flexibility and usage of already existing Modbus syntax – *this breaks old configurations*). - Upload format changed to sending raw response to Modbus commands (*this breaks existing integrations*). #### Fixed - Flushing to avoid invalid byte received from switching from TX to RX. - Modbus mode ASCII now counts received bytes correctly. - DataLength of 7 bits can now correctly be set in config again. ### 0.3.1 - 2019-05-24 #### Fixed - Increased robustness of data reception on higher Baud rates. ### 0.3.0 - 2019-05-15 #### Added - Initial release of Firmware for new Hardware revision (with RS485-addon). - Update Modbus to support all 4 types of registers. #### Changed - Parity bit must not be subtracted from Data bits anymore. `8E1` can now be configured with `8 Data bits, EVEN parity, 1 Stop bit`. ### 0.1.0 – 2018-08-13 #### Added - Original hardware release (with RS-485 on holding PCB). |