Integrations allow exchange data between the Lobaro Platform and other applications.
See: Integrate LoRaWAN Network Server
See: REST Api
Navigate to: Integrations -> HTTP
Forward data from the Lobaro Platform to any HTTP(s) endpoint.
HTTP Method: The HTTP method to use for the request.
Target URL: Any reachable HTTP server endpoint. (Can use Variable Substitution, for details see below.)
Authentication: One of the following authentication schemes can be used:
Bearer
prefix).Headers: List of headers to be set on HTTP request in the format: <FieldName>: <Value>
(e.g. Authorization: Basic QWxhZGRpbjpvcGVuIHNlc2FtZQ==
)
Navigate to: Integrations -> MQTT
Forward data from the Lobaro Platform via MQTT Publish to any MQTT broker.
Broker URL: must be in one of the following formats:
mqtt[s]://host.domain[:port]
tcp[s]://host.domain[:port]
Default port for mqtt/tcp is 1883
. Default port for mqtts/tcps is 8883
.
ClientId: Used on MQTT connect. Default is: lobaro-{RND}
. {RND}
will be replaced by a unique random string.
Username / Password: Used to authenticate with the MQTT broker.
Topic: The MQTT topic to publish sensor data. (Can use Variable Substitution, for details see below.)
Currently we only support username/password authentication for MQTT yet. |
Some fields offer Variable Substitution that will be substituted with content from the forwarded payload or device metadata on execution of the integration.
Variables are enclosed by curly braces.
"lobaro/v1/customer/{device.addr}/up
" will lead to Topic "lobaro/v1/customer/70b3d5e050010b67/up
" when a message is forwarded for a device with the Address 70b3d5e050010b67.
device.addr
: Address of the device.device.name
: Name of the Receiving device inside the platform.device.serial
: Serial Number of the Receiving Device.device.id
: Internal id of device. (Should only be used for self integration on the platform.)organisation.id
: Id of organisation the device is assigned to.
You can also access the content of the forwarded data.
Simply use: {data.PATH.IN.JSON}
Example: If you want to access the WMBUS LinkLayer Id of a telegem of the following form:
You would use {data.mbus.Id}
to habe it substituted with 97277339 in the Topic/Address on forwarding.