Product Identification

Image Removed

TypeLOB-GW-SUN-WMBUSName

Solar Wireless M-

Bus

BUS Gateway

Order number#8000179 

Image Added

Overview

The maintenance-free and lightweight Lobaro Solar Wireless M-Bus Gateway for indoor or outdoor environments collects consumption data from up to 500 commercially available water meters, heat meters, heat cost allocators, etc. with 868 MHz wireless M-Bus radio interface or Sensus RF Bubble Up and forwards them regularly encrypted via NB-IoT

or

, LTE-M1 mobile radio or LoRaWAN (configurable) to the Internet for

daily or frequent

evaluation and further processing.

Thanks to the 100% battery

-

and maintenance free design

and

using the

permanent power supply by the

integrated high-performance solar cell in conjunction with an ultra long life super-capacitor, meter data can be transmitted several times a day in many applications when mounted with daylight incidence, even indoors. The achievable readout intervals can, with a suitable installation location, be many times higher than with our battery-powered variant

and there are no costs for battery changes

without the risk of drained batteries and costly maintenance. In addition to the typical smart metering application for billing

purposes

, this innovative design also enables novel areas of application in the field of predictive maintenance

.

.

The sealed gateway housing is designed to be used indoors and outdoors (IP66).

The gateway does not contain toxic heavy metals and is not considered a hazardous good, it is environmentally friendly as an electronic device can be.

Quick Start

Differences to battery powered variant

StatuscolourBluetitleImportant

This device differs from the battery powered variant in the following ways:

  • The device can't be opened in any way - It was sealed with glue during production to achieve high waterproofing for outdoor use.
  • A LTE-M / NB-IoT SIM card has been already inserted by Lobaro

. Please contact Lobaro if your own sim cards should be inserted during production before sealing
  • . Std. Tarif: 3 MB / per month over 10 years.
  • The only kind of configuration adjustment can be done via the Lobaro platform or LoRaWAN downlinks. The USB cable option is not available.
  • The device is shipped in standby mode. Before first use, it must be activated via the magnetic contact on the housing indicated by a dot.
  • The device uses an audio buzzer instead of an LED for feedback
on
  • of power level and operating status.
  • The default WAN selection is "LTE". Please use the Lobaro Platform to switch to LoRaWAN if this is the needed uplink technology. 

Initial Startup

Shortly (< 1 second) hold an magnet to the dot marking on the housing
  • The daily status uplink is done at 12:00h (UTC+0) instead of 00:00h (UTC+0)

Beside this differences the solar powered variant runs the same firmware and has the same functionalities.

Product Identification

Image Added


TypeLOB-GW-SUN-WMBUS
NameSolar Wireless M-Bus Gateway
Order number

#8000179 


Index

Table of Contents




Quick Start

Initial Startup

  • Release the magnet 
  • The devices indicated the current power level by audio (3-0 range, 3 beeps = fully charged)
  • If the device is in "standby" mode a descending tone is played after the energy level audio indication
  • If the level is not 3 or at least 2 place the device in a position with daylight incidence for some hours and check again later (1)

    To reset the device hold the magnet for 5 seconds+ to the dot

    marking 

    marking and hold it until you hear three fast beeps after the rhythmic sound.

    1. A rhythmic on/off tone sounds until three fast beeps indicate the device reset
    2. Release the magnet
    3. An ascending tone signals the restart / reset of the device
    4. If the device was in standby mode, this flag got reset by this reset / activation.
    5. Login into your Lobaro Platform account
    6. The device will upload it's status after an initial wMBUS collection phase

    (info) Note: If the magnet gets removed before the three fast beeps during the rhythmic sound no reset will be performed.

    Energy Level Check

    To check the device current energy level shortly (< 1 second) hold an magnet to the dot marking on the housing.

    1. Release the magnet 
    2. The
    device is ready for use in the configured operating mode
    1. devices indicated the current power level by audio (3-0 range, 3 beeps = fully charged)
    2. If the device is in "standby" mode a descending tone is played after the energy level audio indication
    3. If the level is not 3 or at least 2 place the device in a position with daylight incidence for some hours and check again later (1)

    Default Configuration

    • Since Firmware 0.15.2: Default CRON: 0 0 12 * * * (Collection and upload once a day during daily status)
      • Note: If the energy is not sufficient the collection + upload cycle will be skipped until enough (see RequiredVoltage parameter) energy has been harvested.
      • Up to Firmware 0.15.1:

    Initial Configuration

      • Default CRON: 0 0 8-18 * * * (Collection and upload every hour between 8h-18h UTC during day time)
    • Collect wireless M-BUS (C1/T1 mode) for 900 seconds (15 Minutes)
    • Upload all data to public Lobaro Platform instance (https://platform.lobaro.com)
    • The default configuration can be reset using the external applied magnet between 12 seconds and 15 seconds. There is a single "Beep" indication after 12 seconds.

    (info) A wireless M-BUS readout and upload can be initiated at any time using the magnetic contact reset method (see below) if the stored energy is sufficient.

    Image Added


    Magnetic triggered functions and audio indications

    Magnetic Contact

    The Solar Wireless M-Bus Gateway has an internal magnetic button switch that can be activated via by holding a neodym magnet at the side of the housing marked with a dot. This can be used to query the current energy level of the internal capacitor and to initiate a reset with subsequent wireless-MBus readout and data upload phase. 

    Device Energy Level Indication

    The Solar Gateway has an internal supercapacitor for energy storage. This capacitor can be charged by the PV panel from 3V up to 3.8V.
    The current filling level of the energy storage can be queried by briefly actuating the magnetic switch:

    1. Shortly (< 1 second) hold an magnet to the dot marking on the housing
      1. Release the magnet 
      2. The devices indicated the current power level by using audio feedback (3-0 range, 3 beeps = fully charged)
      3. If the device is in "standby" mode a fast descending tone is played after the energy level audio indication
      4. If the device is completely discharged, no sound is emitted.
      5. If the internal voltage is below the voltage set by the "RequiredVoltage" parameter, a falling tone will sound to indicate that the current voltage is not sufficient for normal operation.


    Stored Energy
    Supercapacitor
    Internal Voltage Level (max. 3.8V)Audio IndicationCharge + System Mode
    Fully Charged Level > 3.65 V3x BeepTrickle-Charge & Normal
    Good 3.5V > Level < 3.65 V 2x BeepCharge & Normal
    UseableLevel >  RequiredVoltage (Parameter)1x BeepCharge & Normal
    Level not sufficient*Level <  RequiredVoltage (Parameter)Descending toneCharge & Sleep
    Absence of EnergyLevel < aprox. 3.0 VNone / SilenceCharge & Off

    Status
    colourYellow
    titleNote (*)
     

    If the RequiredVoltage parameter is set to a higher voltage than "Good" or "Fully Charged" the Descending tone will be played nevertheless.
    The device will remain in sleep mode until the configured voltage has been reached.

    Standby Mode Indication

    In case the device is in the "Standby" mode, after the signalization of the energy level, the device emits an additional fast decaying tone. In case the internal voltage level is below the RequiredVoltage parameter this leads to two slow and fast descending tones right after each other.

    Manual Device Reset

    Device Restart + Manual Readout

    To (re)start the gateway, the magnet must be held against the gateway at the above position for at least 5 seconds:

    1. To reset the device hold the magnet for at least between 5-6 seconds to the dot marking until you hear three fast beeps after the rhythmic sound.
      1. The stored energy indication feedback is given
      2. A rhythmic on / off tone starts until three fast beeps
      3. Release the magnet
      4. An ascending tone signals the restart / reset of the device
      5. The device performs a complete wireless M-BUS readout cycle with data upload via LTE (NB-IoT or LTE-M) or LoRaWAN.

    (info) If the magnet is removed before at least 5 seconds have elapsed (b), there will be no reset! Then only the current energy level is signaled.

    Device Reset to default parameters

    The default configuration can be reset using the external applied magnet between 12 seconds and 15 seconds. There is a single "Beep" indication after 12 seconds. Default parameters are using the Lobaro Platform (https://platform.lobaro.com) and NB-IoT/LTE-M as upload target. This might be useful if the device needs to be switched back from LoRaWAN to NB-IoT.

    Standby Mode Indication

    In case the device is in the "Standby" mode, after the signalization of the energy level, the device emits an additional fast decaying tone. In case the internal voltage level is below the RequiredVoltage parameter this leads to a slow and fast descending tone right after each other.


    Variant Specific Parameters 

    Normally, the default values of the following solar variant specific parameters should only require an adjustment for special applications with particularly low light incidence or very many consumption meters to be read out.

    NameDescriptionDefault
    Value
    Value Description & Examples
    Standby
    Devices in

    In standby mode

    remain

    the gateway remains in a low-power mode until the user performs an

    initial reset

    "Device Reset" via the magnetic contact. The parameter changes

    from true

    to false after this reset. It can be reactivated via a remote configuration downlink. This mode can be determined via the "Standby Mode Indication" when active.

    (warning) The device can conserve in this mode its energy for some months. If the device has not been exposed to daylight for a very long time, a charging process may be necessary before initial installation.

    true
    • true: Factory default low power sleep mode

    • false: Normal cron based operating mode

    The device is normally delivered with activated standby mode

    so

    to ensure that sufficient energy is available during initial use / installation. Contact Lobaro for a custom configuration if your particular installation process requires a disabled standby mode upon delivery.

    RequiredVoltage
    Required voltage level for normal operating mode. If the voltage in the device is lower, CRON based readouts are skipped until enough energy can be stored from the solar cell.
    3250
    3500

    Voltage level in mV. Range:

    3000mV

    3100mV to

    4000mV

    3700mV.
    Must be

    higher

    greater than RestVoltage parameter. 

    RestVoltage
    Voltage level under which
    a continuous
    an active wireless MBUS readout and LTE/LoRaWAN upload cycle is aborted to prevent a power failure reset.
    3100
    Voltage level in mV. Range: 3000mV to
    4000mV
    3699mV.
    Must be
    lower
    less than RestVoltage parameter. 



    SIM-Card

    The device is delivered as standard with a permanently installed internal SIM card with 500 MB data volume for allowing an initial data volume usage of 3 MB per month over a 10 years period. The utilized cellular networks can be either NB-IoT and or LTE-M from 1nce with network coverage in many different countries. Additional data volume can may be obtained from Lobaro if required, or the SIM card can be transferred to your 1nce accountorganization allowing data volume purchases independent from Lobaro.

    For larger orders with dedicated production runs other (E)SIM cards can be used customer specific. Please contact us directly for this optionLobaro if your own sim cards should be inserted during production before sealing.

    Data Usage

    From field tests we have the following estimates for data usage. This can vary based on the actual configuration an uploaded telegrams.

    3 MB for 8.600 Uplink → avg. 365 Byte per Uplink

    This was measured after ~15 Days with over 500 telegram Uploads per day.



    Physical specifications

    Image Added


    Width133.5mm
    Length133.5mm
    Height25.1mm
    Mounting4x M4 Threads with 100mm x 100m spacing
    , like "VESA-Mount" 
    MaterialABS+PC (Fireproof)
    Rating
    IP54
    IP66 (Suitable for outdoor use)
    Weight185g
    Drawing
    View filenameheight250



     



    Mounting Options

    Warning
    titlePlease Note

    The responsibility for selecting a durable and stable mounting method lies with the customer. 



    Wall Mounting Kit

    Image AddedImage AddedImage Added


    Pole Mounting Kit 

    Image AddedImage AddedImage Added

    • Lobaro Article:
      Status
      title#8000196
    • Datasheet: Bracket_Solar_GW_Webside.pdf
    • (warning)  Install the Solargateway with antenna alignment upwards (green dot or mark on the housing for the magnet in downward orientation).


    Mounting Instructions & Examples

    Outdoors

    • (warning) In hot regions with regular outdoor temperatures above 25°C the device must be placed in a shady location without direct sunlight incidence.
      •  Failing to keep internal the temperatures at a moderate level may result in a reduced device lifetime.
    • For outdoor installations, any location is normally suitable for transmitting data at least multiple times a day.

    Indoors

    • When selecting an indoor installation location, make sure that at least some daylight can reach the gateway.
    • The direct proximity to a window is ideal.
    • Even low non optimal light levels could be sufficient for some data transmissions per month.

    Antenna Shielding

    • (warning) Avoid antenna shielding, e.g. using a solid metal mounting plate, in the red marked minimal keep-out area.
    • (info) For optimal antenna performance do not block the keep-out area shown in Drawing and in pictures below:

    Doku 1.pngImage AddedSolarGW-Radiation.pngImage Added

    Indoor near window mount

    Housing attached using double sided tape. Location good enough for multiple readings during daytime

    Mounting with backplate

    To mount the unit to a wall, the optional plexiglass back plate is available from Lobaro.

    Image RemovedImage RemovedImage Removed

    Mounting with threaded magnets

    Will follow.

    Mounting Option with cable tie clips

    Use externally available GSM-2C clips and cable ties.
    The 2-4 clips can be mounted by M4x8 Countersunk head screw to the Lobaro Solar Gateway.

    Image Removed

    Mounting Option with hook & loop tape

    Will follow.

    Example Mountings

    Indoor Near Window Mount

    Housing attached using Hook & Loop Tape. Location good enough for some readings per day.

    Outdoor mounting in the basement staircase

    Housing attached using GSM-2C clips (4 pcs.) and cable ties. Covered outdoor location good enough for hourly readings.

    Outdoor pole mounting 

    The gateway was bolted to a wooden board, which was then attached to the pole. Outdoor location good enough for hourly readings 24h / day.

    Image AddedImage Added

    In this test, the internal antenna was compared with an external one, as well as a larger internal supercapacitor with the standard size.
    Therefore, four gateways were mounted on one pole at the same time.

    Outdoor impressions

    Image AddedImage Added



    Anbindung an das Smart Meter Gateway (🇩🇪)